Chapter 3 – Voice Commands
Command: +VNH= Automatic Hang-up Control
Description:
This command enables or disables automatic hang ups.
Syntax: +VNH=<hook>
Values:
<hook>
Decimal number corresponding to the selected option.
0 Modem enables automatic hang ups as is normal in other modes.
1 Modem disables automatic hang ups usually found in the other non-
voice modes.
2 The modem disables automatic hang ups in the other non-voice modes.
The modem performs a “logical” hang up (returns OK result code).
Default :
Report Commands:
0
+VNH? Reports current or selected values.
+VNH=?
Reports supported range of parameter values.
Command Responses:
Automatice Hang-up Command Responses
Command
No Carrier Present
ATH
ATZ
DTR & D2
+VNH=0 Y Y Y Y
+VNH=1 N Y Y Y
+VNH=2 N N N Y
Notes:
Y = will hang up; N = will not hang up
How +VNH is reset:
DTE uses +VNH command to change the setting.
DTE issues another +FCLASS mode change without issuing another +VNH.
A hang-up event occurs (see this table).
DTE issues +VIP command.
Command: +FLO
Function:
Values:
Result Codes:
Description:
Flow Control
Select Flow Control Method
0, 1, 2, 3-255
OK or ERROR
The +FLO? command lets you select the method of flow control provided and used by the
modem. If +FLO=0, some other method (such as credit flow control) is used. The Xon-Xoff
method is required. Xon is the ASCII character <DC1> (11 hex). Xoff is the ASCII
character >DC3> (13 hex). CCITT V.24 circuits 106 and 133 are optional flow control
methods. If circuits 106 and 133 are not used (+FLO<>2), then circuit 106 is held On
whenever +FCLASS=8.
In Voice mode, circuit 105 has no effect on the state of transmitted data. (Circuit 133
normally reverts to use as circuit 105 (RTS) when not used for Flow Control.)
+FLO=0 Disables Xon-Xoff and 133/105 flow control
+FLO=1 Enables Xon-Xoff flow control in either direction
+FLO=2 Enables CCITT Circuit 133 for flow control of the modem by the PC; use
CCITT Circuit 106 for flow control of the PC by the modem.
+FLO=3-255 Reserved for future standards.
Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273F)
29
相关PDF资料
MT5692SMI-IP-92 V.92 SERIAL DATA ONLY
MT5692SMI-V-34 V.34 DATA/FAX SOCKET MODEM
MT5692SMI-X-L-92 V.92 SERIAL DATA
MT9234MU MODEM V.92 DATA/FAX USB WORLD
MT9234ZBA-NAM MODEM V.92 WORLD DATA/FAX
MT9234ZBA-USB-CP MODEM V.92 DATA/FAX USB WORLD
MT9234ZBA-USB MODEM V.92 DATA/FAX WORLD USB
MT9234ZPX-PCIE-CP MODEM V.92 DATA/FAX/VOICE WORLD
相关代理商/技术参数
MT5656ZDX-CP 功能描述:MODEM V.92 DATA/FAX 25 PACK RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZDX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT5656ZDX-EU 功能描述:MODEM V.92 DATA/FAX EU BUNDLE RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZDX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT5656ZDX-GB/IE 功能描述:MODEM V.92 DATA/FAX EK BUNDLE RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZDX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT5656ZDX-NPS-CP 制造商:Multi-Tech Systems 功能描述:V.92 DATA/FAX MODEM (NO POWER SUPPLY) (25 MODEMS) - Bulk
MT5656ZDX-V 功能描述:MODEM V.92 VOICE/DATA/FAX RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZDX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT5656ZDX-V-CP 制造商:Multi-Tech Systems 功能描述:V.92 VOICE/DATA/FAX MODEM (25 MODEMS) - Bulk
MT5656ZDX-V-EU 功能描述:MODEM V.92 DATA/FAX/VOICE BUNDLE RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZDX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT5656ZDX-V-GB/IE 功能描述:MODEM V.92 DATA/FAX/VOICE BUNDLE RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZDX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装